Programming Flash

Additional Feature Information
Flash

Setting Up Flash

Set up the Flash options.

  1. 1612-04: PBX/Centrex Flash Timer [System: Timers: CO Interface Card: Outgoing (1612): Loop Flash Time]
    Set the Flash timer for compatibility with the connected Centrex or PBX.
    Option Description
    16-4080 mS. [Default] = 800 mS.
  2. 1403-01: Flash for Single Line Set [System: Class of Service: SLTs: SLTs(1403): Flash for Single Line Sets]
    Enabling this option allows a single line extension user to be able to hookflash.
    Option Description
    No (0) Disabled.
    Yes (1) [Default] Enabled.
  3. 2102-01: Class of Service [Stations: Config: Setup: Access (2102): Class of Service]
    Assign Class of Service to extensions.
    Option Description


    1-15
                                        


    Class of Service level 1-15.
    [Default] for extension 300 = 1.
    [Default] for all other extensions = 2.